background image

FUEL BED (continued)

Fit the glass door assembly with the 4 screws provide in
the positions indicated.  Ensure that the screws are tight-
ened so as to achieve a good seal between the glass
frame gasket and the firebox.

The fire is designed to operate correctly with the sup-
plied components according to the instructions.  Never
add coals.  Never put combustible or non-combustible
materials, rubbish or other matter into the fire. Please
note that it takes approximately 15 minutes for the full
flame effect to be achieved.

FITTING THE DECORATIVE FRAME AND HOOD

The appliance is supplied with a decorative frame and hood.
The frame attaches to the firebox using either four magnetic pieces, or as a three piece clip-on
assembly. The side pieces of the clip on assembly should be pushed into position first, followed
by the top bar, which should overlap the sides. For the single piece assembly, magnets should
be fitted to the steel backing plates. A plastic pro-
tective coating may be applied to the face of the
frame assembly, which should be removed at this
stage.

IMPORTANT : Due to the possibility of sharp
edges, care should be taken when handling the
three piece frame components. The use of pro-
tective gloves is recommended.

Place the firefront into position in front of the fire
and slide the ashpan door into place. Do not use
any other firefront other than the one supplied
with this appliance. The firefront shown in these
instructions may differ form the one supplied with
the appliance.

Fit the convector hood to the firebox by engaging
the two mounting hooks into the relevant slots in
the firebox. The hood should be pressed inwards and downwards to secure into position.

TESTING AND COMMISSIONING

As previously mentioned, firstly turn on and test the gas supply up to the fire for any leaks, in
accordance with current Approved Codes of Practice (ACOPs).

OPERATING THE APPLIANCE

The pilot is visible through the left hand side of the matrix. 

Push in and turn the control knob to the SPARK position, and hold there for
a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise, and
repeat.

When the pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If the pilot extinguishes during use, wait
three minutes before repeating the ignition procedure. To achieve the HIGH setting, push the
control knob in slightly and continue turning anti-clockwise to the high position. The main burn-
er should light after a few seconds. To decrease the setting to LOW, turn the control knob clock-
wise to the low setting.To turn to the PILOT position from the HIGH or LOW positions, press the
control knob in, and return to the pilot position and release. To turn the fire OFF, keep the knob
pressed in, return to the off position and release.

10

9.0

10.0

11.1

11.0

Содержание P30G FXL01

Страница 1: ...EL LE ES SS S I IN NS SE ET T M MO OD DE EL L P P3 30 0G G I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S All instructions must be handed to user for...

Страница 2: ...FXL01...

Страница 3: ...installed in a living room This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume i...

Страница 4: ...vre is also required To reduce the possibility of draughts entering the room via the air vent we recommend the use of Black Hole or Vortex type vents featuring internal baffles It should be noted that...

Страница 5: ...con structed clearances and insulation must be as for a timber constructed wall 2 Insertion into a purpose made opening in the inner leaf of a cavity wall or a disused conven tional fireplace opening...

Страница 6: ...h this appliance must be adequately sealed to the wall and floor to prevent excess draughts from around the back of the fire The temperature rating of any surround used must be 150 C minimum A combust...

Страница 7: ...Ensure that the gas supply is isolated before commencing installation of the appli ance The fireplace opening and environment must be in compliance with specifications laid down in the appropriate se...

Страница 8: ...l of a property and is achieved by using either a surround with extended rebate or a false chimney breast of minimum 90mm internal depth A false chimney breast should be installed taking into account...

Страница 9: ...possible centrally under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lintel always bed on mortar and securely slate pi...

Страница 10: ...ment IGE UP 7 Special attention must be paid to the location of studwork frames of the inner leaf and the appli ance positioned accordingly Wires and pipes that run within the wall must also be taken...

Страница 11: ...loss from the room when the fire is off GAS SUPPLY When the opening is ready for installation of the fire the gas supply can be routed via knockout holes Examples are shown in the diagram in section 6...

Страница 12: ...ing a suitable spanner to pull the appliance back into position to allow an even pull around the fireplace opening Visually inspect and repeat if necessary to achieve a good fit Note Surplus cable MUS...

Страница 13: ...supplied with this appliance The firefront shown in these instructions may differ form the one supplied with the appliance Fit the convector hood to the firebox by engaging the two mounting hooks into...

Страница 14: ...nce must not be commissioned and the manufacturer should be contacted for guidance BRIEFING THE CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and...

Страница 15: ...n serviceable item If this needs replacement remove the two M5 securing screws and remove the complete valve Replacement must be done using original manufacturers parts Re assembly in the reverse of r...

Страница 16: ...atalytic converter remove the hood and front fret then the glass panel The cat alytic converter retaining clamp is secured with 4 nuts and slip proof washers located on the inside of the firebox at th...

Страница 17: ...then cuts off Check pilot has extinguished Ensure room sizing and ventilation are adequate See Section 3 1and 4 1 Loose or faulty thermocouple rectify Blocked pilot replace Dirt or lint in pilot aera...

Страница 18: ...oncerned The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob control panel and ash pan cover This appliance is intended as a secondary...

Страница 19: ...toring system ODS system The requirements of other appliances operating in the space or room must be taken into con sideration when assessing ventilation requirements this will have been carried out b...

Страница 20: ...embly The hood should be lifted and pulled outwards Next remove the door by removing the 2 screws and disengaging the 2 lugs at the bottom The glass can be cleaned using a proprietory hob cleaner Test...