Constant Quality Monitoring
- technical details
124
F.4. Graph scores
Graphs are scored based on settings in the config. Each 100 second sample has a score which is included in
the csv and xml lists for any graph. The score is also totalled for a graph as a whole and included in the csv
and xml list of all graphs. This total is done by multiplying the last score by 864, the previous by 863, and so
on for the previous 24 hours.
F.5. Creating graphs, and graph names
Graph names are text and up to 20 characters. Only letters, numbers, @, -, and . are allowed. All other characters
are removed. It is recommended that names complying with this are used. Any graph name that you try and use
that is too long will be replaced with one that uses part of the name and a hash to try and ensure a consistent
unique graph name is applied.
Graphs can be defined in some configuration settings such as interface names.
The number of graphs is limited depending on memory, but the design is to allow for 100,000 distinctly named
graphs. Dynamic circuits simply do not have graphs on them if this number is exceeded. Graphs not used for
more than the data retention time are discarded automatically.