Version: July 2020
6
Weather Housing
•
The gas supply pipe will need to be run into the weather housing under the burner, as this is where the
copper tube with the gas supply connects to the GD6 burner.
•
The electrical supply cable will need to be run into the weather housing (must be a minimum of 1.0mm 3
core cable), ensure 1000mm of cable is at the centre of the cavity, as this is where it will connect to the GD6
burner.
•
The electrical cable connects to the fan/fans (1.0mm 3 core cable).
•
In order to access the gas and electrical connections inside the weather housing, it is necessary to first
remove the burner.
•
Remove the outer front cover (3 x screws across the top and 2 x screws across the front).
•
To refit the outer front cover, simply reverse the removal process.