Step 4: Connect and test electrical supply
•
All electrical connections must meet the requirements of AS/NZS 3000 standards and be installed
and certified by a suitably qualified person.
•
In order to access the electricals, it is necessary to first remove the burner tray
and weather housing front
cover
.
•
Remove the burner tray and weather housing front cover by following the
‘Burner Tray Removal Process
’
and
‘
Weather
Housing’
of this guide.
•
With the burner tray and weather housing front cover removed the electrical connections between the
appliance and the wall isolation switch can be seen, use 3 core (minimum 1mm) cable from the wall isolation
switch.
•
Following these connection details, using the 3 core cable that has been run at site, connect the wall
isolation switch to the appliance
•
IMPORTANT: Before testing, ensure the gas valve is
turned OFF.
•
Test electrical functions by switching the wall isolation switch to the appliance ON.
•
Using the remote control, switch the appliance ON, following the
‘GD6 Operating Instructions’
in this guide.
•
The fan will start and after approximately 25 seconds, the pilot will spark. Because the gas supply is turned
off, the pilot will spark for approximately 25 seconds then automatically switch off.
•
Using the remote control switch the appliance OFF, following the
‘GD6 Operating Instructions’
in this
guide.
•
Switch the wall isolation switch to the appliance OFF. Electrical testing is complete.
•
Install the burner tray by following the
‘Burner tray installation process’
in this guide.