background image

Version: July 2020                                                                       

                    

 

 

 

 

This GD6 RB appliance is supplied with the chosen firebox lining or ready for the client-

supplied firebox lining. 

 

Note

: T

ake care when removing the top fixing bracket. The top of the Fire box lining will fall forward with the 

bracket removed. 

 

1. Remove the top three lining fixing brackets. 5mm cap screws.  

2. Allow the top of the lining to fall forward. 

3. Carefully lift the lining up and out of the base channel.  

4. Place the lining in a safe place. 

5. The lining on the base (either side of the 

burner) fits into the channel. 

6. Remove the base lining by carefully lifting the lining at the joint or at one end.  

7. T

o refit the firebox lining simply reverse the removal process. 

 

 

 

Содержание GD6 1200

Страница 1: ...GD6 Recessed Burner Remote Control Installation Guide Operating Instructions Warranty...

Страница 2: ...that a fireguard complying with BS 8423 2002 is used in the presence of young children the elderly or infirm NOTE This GD6 RB appliance is fitted with an Oxyprotector Oxygen depletion pilot Under NO c...

Страница 3: ...materials The exception to these minimum clearances is the base and the front surround panels of the appliance the base can safely sit directly upon combustible e g timber and non combustible e g conc...

Страница 4: ...stable surface GD6 RB 1400 Input 20 28 MJ h Two gas injectors one at the right and one at left hand sides of the burner tray GD6 RB 1600 Input 30 38 MJ h Two gas injectors one at the right and one at...

Страница 5: ...he pilot meanwhile holding up the pilot end lower the burner tray down and move towards the pilot in one movement Ensure the burner tray is located correctly into the burner bracket and the jets are a...

Страница 6: ...a minimum of 1 0mm 3 core cable ensure 1000mm of cable is at the centre of the cavity as this is where it will connect to the GD6 burner The electrical cable connects to the fan fans 1 0mm 3 core cabl...

Страница 7: ...lining into the appliance Failure to place the firebox lining correctly may result in the appliance performing inef ciently Dark tile lining supplied as default option Black slate 9mm Size 600mm x 600...

Страница 8: ...he bracket removed 1 Remove the top three lining xing brackets 5mm cap screws 2 Allow the top of the lining to fall forward 3 Carefully lift the lining up and out of the base channel 4 Place the linin...

Страница 9: ...pable of supporting a 200kg load In order to provide maximum positioning flexibility the base of the appliance has two fixing brackets with two 30mm long slots in each The two xing brackets will clamp...

Страница 10: ...witch Following these connection details using the 3 core cable that has been run at site connect the wall isolation switch to the appliance IMPORTANT Before testing ensure the gas valve is turned OFF...

Страница 11: ...Version July 2020 11 Fan for GD6 1500 1600...

Страница 12: ...sure against rating plate specifications Using the remote control switch the appliance OFF following the GD6 Operating Instructions in this guide In the unlikely event that the rating plate is not att...

Страница 13: ...dium correctly may result in the appliance performing inefficiently Open the firebed cardboard box and identify firebox mediums River Rocks option has two firebed mediums Clay balls 3 bags White rocks...

Страница 14: ...our clay balls directly into burner slots Fill burner up to top of burner tray Use hand to spread out and push under burner Using a small Allen key or similar remove any dust that may have fallen into...

Страница 15: ...ing edge of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow the...

Страница 16: ...ching edge of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow t...

Страница 17: ...dge of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow the GD6...

Страница 18: ...g edge of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow the G...

Страница 19: ...e of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow the GD6 Op...

Страница 20: ...edge of burner tray Missing flames along length of burner Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Follow the GD6...

Страница 21: ...owing the GD6 Recessed Burner Operating Instructions on the next page show the owner how to switch the appliance ON and OFF using the remote control and how to switch between HIGH and LOW settings If...

Страница 22: ...ly switch off when your room has reached your desired temperature If you d like the flame back simply switch to manual mode and switch the flame on again This appliance is operated by a remote control...

Страница 23: ...ON position Then press the On Off Key on the remote control The appliance will beep the LCD display will display several active icons room temperature AND WILL IGNITE AFTER 20 25 SECONDS To switch th...

Страница 24: ...height each time it is pressed Fig 3 If the Up Arrow Key is pressed while the appliance is switched on but the flame is off the flame will come on in the high position A single beep will confirm rece...

Страница 25: ...Thermostat function adjusts the flame height in accordance with the difference between the set temperature and the actual room temperature As the room temperature gets closer to the set temperature th...

Страница 26: ...lot light settings IPI and CPI The default setting is IPI If you live in a VERY cold environment it can be changed to CPI which allows easier lighting This is most likely a feature you will never need...

Страница 27: ...hat happens if I break lose my remote control Use your spare remote control that was delivered with your appliance which you will have to pair to your appliance much like pairing a Bluetooth device to...

Страница 28: ...n 1 Low gas supply 2 Low or poor pilot flame 3 Signal to flame rectifier interrupted 1 Check gas supply 2 Check flame size and pilot flame pressure 3 Check flame rectifier and wire to sit pack Flame i...

Страница 29: ...warping if a firebox outer skin or support frame defect occurs contact The Fire Dept and the defect will be repaired or replaced at our discretion with all costs covered The Fire Dept warrants the SI...

Отзывы: