26
C. HOSE WORK WITH RADIO REMOTE TRANSMITTER:
1. Begin with the engine around 1/4 throttle (1,400 RPM).
2. Close recirculation valve. If using an extension hose connected to the discharge boom, open
the discharge valve. If using the hose reel, close the discharge valve and open the pump take-
off valve to the hose reel.
3. Make sure all switches are in the OFF position and all dials are in the ZERO (0) position.
4. Switch Remote On/Off switch on the control panel to the ON position.
5. When the operator is in position, engage (turn on) pump using the remote transmitter and in-
crease throttle to the desired output.
NOTICE
To quickly shut off the engine at any time, press the red E-Stop button on the transmitter. To restart the
engine, the key switch on the control panel must be returned to the OFF position and then restarted.
6. When finished spraying, turn the pump off and decrease the engine throttle to idle.
CAUTION
When using the radio remote control option, the secondary operator(s) must be aware that the
machine can be activated remotely at any time after the Remote On/Off switch on the control
panel is switched ON. If any maintenance or troubleshooting must be performed while the
engine is running, the Remote On/Off switch must be in the OFF position. Failure to comply
could result in minor personal injury, or product or property damage.
RELOADING PROCEDURE
1. Start at step 2 in LOADING on pages 21 and 22.
2. After last load of the day, refer to CLEANING AND MAINTENANCE on pages 32 and 33.
3. If the unit is equipped with an Air Flush System, refer to Air Flush System Parts and Operator's
Manual.
Содержание HydroSeeder TITAN280
Страница 25: ...19 NOTES...
Страница 44: ...38 3 2 2 8 1 10 4 6 2 6 9 1 2 9 7 8 LUBRICATION LOCATIONS...
Страница 46: ...40 NOTES...
Страница 52: ...TITAN MMA2017 Rev D 46 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 1 5 2 2 6 3 4 7...
Страница 54: ...TITAN MMA2017 Rev D 48 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 2 5 5 3 1 4 7...
Страница 56: ...TITAN MMA2017 Rev D 50 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 7 6 4 1 4 4 5 3 2 6 4...