25
A. PUMP TAKE OFF SYSTEM OR HOSE REEL WITH REMOTE VALVE:
1. Open recirculation valve, close boom discharge valve, and close remote valve at the end of the
hose.
2. Engage clutch. When stream is flowing freely through the recirculation line, open the pump
take-off valve.
CAUTION
The high pressure on the hose can exert strong forces, causing the potential for the hose
operator to lose control of hose or footing. The hose will require additional hose holders when
this operation occurs on slopes. Open the pump take-off valve and the remote valve slowly
and only after the hose operator is firmly positioned and has firm control of hose. Failure to
comply could result in minor to moderate personal injury. Failure to comply could also result
in product or property damage.
3. With the engine running at approximately 2,000 RPM, open the remote valve at the end of the
hose to discharge the load.
4. When finished spraying, close the remote valve, disengage the clutch, and stop the engine. If
using fiber mulch, retain as much water as possible in the hose by elevating the hose ends or
by coupling the hose ends together.
5. If another load is to be done, see RELOADING PROCEDURE on page 26. If finished for the
day, follow the clean-up procedures under DAILY on page 32.
DANGER
The recirculation valve must be open when using a remote valve. Failure to comply will result
in death or serious injury.
B. EXTENSION HOSE SYSTEM - WITHOUT REMOTE VALVE:
1. Connect extension hose into the end of discharge boom.
2. A person controlling the end of the hose directs a second operator at the machine to control the
clutch and adjust the engine speed.
CAUTION
Since the extension hose will be seeing the full output of the pump with the recirculation valve
closed, the equipment operator and individual at the end of the hose should exercise extreme
care when operating the unit on high pressure. The high pressure on the hose can exert strong
forces, causing potential for the hose operator to lose control of hose or footing. The hose will
require additional hose holders when operation occurs on slopes. Engage the clutch only after
the hose operator is firmly positioned and has firm control of hose. Failure to comply could
result in minor to moderate personal injury. Failure to comply could also result in product or
property damage.
3. When hose operator is ready, signal the second operator to engage clutch and slowly increase
the engine RPM until the desired discharge pressure is reached.
4. When finished spraying, disengage the clutch, stop the engine, and close the discharge valve.
If using fiber mulch, retain as much water as possible in the hose by elevating the hose ends or
by coupling the hose ends together.
5. If another load is to be done, see RELOADING PROCEDURE on page 26. If finished for the
day, follow the clean-up procedure described in DAILY CLEANING AND MAINTENANCE on
page 32.
Содержание HydroSeeder TITAN280
Страница 25: ...19 NOTES...
Страница 44: ...38 3 2 2 8 1 10 4 6 2 6 9 1 2 9 7 8 LUBRICATION LOCATIONS...
Страница 46: ...40 NOTES...
Страница 52: ...TITAN MMA2017 Rev D 46 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 1 5 2 2 6 3 4 7...
Страница 54: ...TITAN MMA2017 Rev D 48 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 2 5 5 3 1 4 7...
Страница 56: ...TITAN MMA2017 Rev D 50 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 7 6 4 1 4 4 5 3 2 6 4...