SBPC-21-EN External Connections/Indicators
SBPC-21-EN mounting considerations are simplified as all connections to the SBPC-21-EN are on the
same side of the box.
Figure 1-3: SBPC-21-EN Side View
Connection to FifeNet is
accomplished using the
standard FifeNet connector.
Configuration is also
downloaded to the device
using this connection.
Device and network status
LED’s. These indicators
provide feedback for
network troubleshooting.
Connection to Ethernet is
accomplished using the
standard RJ-45 connector.
Switch Value = 1-255
The IP address configuration switches can be used to configure
the IP address in an intranet network. The first three values of
the IP address are fixed at 192.168.0 and the dip switch value
represents the binary value of the last digit of the IP address.
The subnet mask is 255.255.255.0 and the default Gateway is
0.0.0.0.
In the switch example shown above, the IP address is set to
192.168.0.20.
Switch
1 2 3 4 5 6 7 8
OFF OFF OFF ON OFF ON OFF OFF
Switch Value = 0
Set the switches to zero as shown below to use a
DHCP/BootP server if present or use the internally stored IP
address. If a DHCP/BootP server is not present, the stored IP
address will be used. See the section SBPC-21-EN Network
Configuration for details about how to store an IP address.
Switch
1 2 3 4 5 6 7 8
OFF OFF OFF OFF OFF OFF OFF OFF
07-02-2004
Figure Sheet 1-849-C
Page 3
Содержание SBPC-21-EN
Страница 2: ...07 02 2004 Figure Sheet 1 849 C...
Страница 4: ...07 02 2004 Figure Sheet 1 849 C Page ii...
Страница 18: ...07 02 2004 Figure Sheet 1 849 C Page 12...
Страница 22: ...07 02 2004 Figure Sheet 1 849 C Page 16...
Страница 38: ...07 02 2004 Figure Sheet 1 849 C Page 32...
Страница 42: ...07 02 2004 Figure Sheet 1 849 C Page 36...