Status Data Block (cont’d)
Register 0x412, 0x418, 0x41E:
Drive-Specific Alarm Register.
0x412
– Drive 1, Contacts 0x4120 through 0x412F
0x418
– Drive 2, Contacts 0x4180 through 0x418F
0x41E
– Drive 3, Contacts 0x41E0 through 0x41EF
ALARM REGISTER (SR3)
Contacts 0x412*, 0x418*, 0x41E* (* = 0 - F)
F E D C B
A
9
8
7 6 5 4 3
2
1
0
Description
1
Encoder – Stroke Alarm
1
Web Measurement Alarm
1
Loss of Null
1
ASC (Automatic Sensor Control) Active
1
Fault – Serial Power
1
Drive Centered
1
Drive in Shutdown
1
Counterclockwise Maximum Motor Speed
1
Clockwise Maximum Motor Speed
1
Motor Blocked; Motor Current
1
SSC (Sensor Signal Comparator) Active
1
Counterclockwise Maximum Motor Current
1
Clockwise Maximum Motor Current
1
Valid Motor Installed
Register 0x413:
Drive 1 Encoder Value, Contacts 0x4130 through 0x413F
Register 0x419:
Drive 2 Encoder Value, Contacts 0x4190 through 0x419F
Register 0x41F:
Drive 3 Encoder Value, Contacts 0x41F0 through 0x41FF
NOTE:
These registers contain the normalized values of the connected sensors.
Data Type:
Signed 16-bit number.
Range:
-32768 to +32767