24/40
Operating instructions EtherCatWPM Gateway Fieldbus
Operation
Battery
Voltage of the battery in mV
Serial Number
Serial number of the WPM data holder
RSSI
Signal strength of the Bluetooth signal in percent
Name
Abbreviated name of the WPM data holder
Sensors
Number of WPM pressure sensors assigned to the WPM data holder.
TXPDO3 Sensor Data
Actual values of the currently selected WPM pressure sensor
These values relate to the index of the selected WPM pressure sensor displayed in ‘Active Sen-
sor’ TxPDO1.
If ‘Active Sensor’ in TxPDO1 is 0, the data are invalid.
State
Device status
Pressure
Last measured pressure value of the WPM pressure sensor in bar
Temperature
Last measured temperature of the WPM pressure sensor in °C
Battery
Last measured battery voltage of the WPM pressure sensor in mV
Serial Number
Serial number of the WPM pressure sensor.
RSSI
Signal strength of the Bluetooth signal in percent
Bit
Meaning
0 (0x01)
Pressure warning
1 (0x02)
Temperature warning
2 (0x04)
Battery warning
3 (0x08)
Pressure alarm
4 (0x10)
Temperature alarm
5 (0x20)
WPMconfig measurement
6 (0x40)
ACTIVE mode (nonsleep)
7 (0x60)
LOCK