6.1
LED displays on the device
On the WPM Gateway itself, several LEDs display the operating statuses of the device and the
interfaces.
LED
Function
Description
Power
Status for internal voltage
supply
The LED shines green if
Thesupply voltage is correctly applied and the
internal voltage regulators work correctly.
CPU
Boot status
The LED shines green
if the CPU is properly started.
The LED shines red
if the internal initialisation of the Bluetooth module
has failed.
Bluetooth
Bluetooth communication
status
The LED blinks green
if there is no communication with FIBRO devices
(WPM pressure sensors or WPM data holders).
The LED shines green
if there is communication between the CPU and
Bluetooth.
Gateway
Pairing status
LED is out
if there is no pairing.
The LED blinks green
if the pairing process is active.
The LED shines green steadily
if the WPM Gateway is connected to a pressing
tool.
The LED blinks red
if a pairing procedure can be started using the
“login button” on a data holder.
ETC RUN
EtherCAT status
The LED shines green
if the EtherCAT is properly initialised and is run-
ning
ETC in/out
Link status
The LED shines green
if an EtherCat partner is properly connected with
the respective connection.
Содержание 2480.00.91.40
Страница 34: ...34 40 Operating instructions EtherCatWPM Gateway Fieldbus Technical data 9 2 Technical drawing ...
Страница 37: ...Operating instructions EtherCatWPM Gateway Fieldbus 37 40 Appendix 11 APPENDIX 11 1 Personal notes ...
Страница 38: ...38 40 Operating instructions EtherCatWPM Gateway Fieldbus Appendix ...
Страница 39: ...Operating instructions EtherCatWPM Gateway Fieldbus 39 40 Appendix ...