Operating instructions EtherCatWPM Gateway Fieldbus
23/40
Operation
TXPDO1 information
Tool State
Number Of Tools
Number of WPM data holders received via Bluetooth.
Number Of Sensors
Number of WPM pressure sensors received via Bluetooth.
Active Tool
Confirmation of which WPM data holder transferred the data to ‘TXPDO2 Tool Data’.
If ‘Active Tool’ = 0, the data from all WPM pressure sensors received via Bluetooth can be read.
Active Sensor
Confirmation of which WPM data sensor transferred the data to ‘TXPDO3 Sensor Data’.
Monitored Tool
Index of the WPM data holder which was used to perform a pairing or which
WPM data holder is currently being monitored.
Command
Confirmation of the command performed.
TXPDO2 Tool Data
Actual values of the currently selected WPM data holder.
These values relate to the index of the selected WPM data holder displayed in ‘Active Tool’ Tx-
PDO1. If ‘Active Tool’ in TxPDO1 is 0, the data are invalid.
State
Device status
Bit
Meaning
0 (0x01)
Warning message
1 (0x02)
Alarm message
2 (0x04)
At least one sensor malfunctioned during the tool monitoring (no Blue-
tooth message received for 120 seconds)
4 (0x10)
Active pairing process
5 (0x20)
Pairing completed (tool monitoring is active)
All others
--
Bit
Meaning
0 (0x01)
--
1 (0x02)
--
2 (0x04)
Battery warning
3 (0x08)
--
4 (0x10)
--
5 (0x20)
Bit for PC measurement, PC has switched to ACTIVE
6 (0x40)
Bit ACTIVE mode
7 (0x60)
Bit for LOCK
Содержание 2480.00.91.40
Страница 34: ...34 40 Operating instructions EtherCatWPM Gateway Fieldbus Technical data 9 2 Technical drawing ...
Страница 37: ...Operating instructions EtherCatWPM Gateway Fieldbus 37 40 Appendix 11 APPENDIX 11 1 Personal notes ...
Страница 38: ...38 40 Operating instructions EtherCatWPM Gateway Fieldbus Appendix ...
Страница 39: ...Operating instructions EtherCatWPM Gateway Fieldbus 39 40 Appendix ...