Operating instructions EtherCatWPM Gateway Fieldbus
13/40
Commissioning
5.2.2
Digital outlets
The WPM Gateway has 4 digital outlets.
24V DC nominal voltage.
Digital outlets are galvanically isolated from the device supply.
Recommended connection:
•
Line
•
M12 socket
•
8-pole, A-coded
•
Maximum line length: 30 metres
NOTICE
Electrical fuse
Install line protection to protect the device .
Destruction of device in the event of overload.
Destruction in the event of an error.
1
2
6
8
4
7
3
5
X71 plug
M12 pin,
8-pole, A-coded
Digital outlets
Function
Pin 1
D0_OUT
+24V, 0.5A
Digital outlet 0
Signal light is green,
status is ok. High is active.
Pin 2
D1_OUT
+24V, 0.5A
Digital outlet 1
Signal light is orange,
status is warning. High is active.
Pin 3
D2_OUT
+24V, 0.5A
Digital outlet 2
Signal light is red,
status is error. High is active.
Pin 4
D3_OUT
+24V, 0.5A
Digital outlet 3
Signal light is blue,
Pairing is taking place. High is ac-
tive.
Pin 5
NC
NC
Do not assign
Pin 6
NC
NC
Do not assign
Pin 7
+24V_DOUT
Supply for digital
outlets 0-3
Supply, galvanically isolated
Pin 8
0V_DOUT
Reference poten-
tial for digital out-
lets 0-3
Reference potential, galvanically
isolated
Содержание 2480.00.91.40
Страница 34: ...34 40 Operating instructions EtherCatWPM Gateway Fieldbus Technical data 9 2 Technical drawing ...
Страница 37: ...Operating instructions EtherCatWPM Gateway Fieldbus 37 40 Appendix 11 APPENDIX 11 1 Personal notes ...
Страница 38: ...38 40 Operating instructions EtherCatWPM Gateway Fieldbus Appendix ...
Страница 39: ...Operating instructions EtherCatWPM Gateway Fieldbus 39 40 Appendix ...