Operating instructions EtherCatWPM Gateway Fieldbus
25/40
Operation
TXPDO5 digital in / relay
Status of the digital inlets or the relays, states of the WPM Gateway (activated == high)
RxPDO1 Activate
Active Tool
Index of the WPM data holder whose data should be displayed in TxPDO2 or the index of the
WPM data holder to be monitored (pairing).
Active Sensor
Index of the WPM pressure sensor whose data should be displayed in TxPDO3
If the index in ‘Active Sensor’ is set, the data of the WPM pressure sensors assigned to the WPM
data holder can be read.
If ‘Active Tool’ in TxPDO1 is 0, ‘Active Sensor’ can be used to read the data from all the WPM
pressure sensors received via Bluetooth.
Command
Sends a command to the WPM Gateway
The following commands are defined:
Bit
Meaning
0 (0x01)
Digital inlet D0_IN
1 (0x02)
Digital inlet D1_IN
2 (0x04)
Digital inlet D2_IN
3 (0x08)
Digital inlet D3_IN
4 (0x10)
REL_RUN_OUT
5 (0x20)
REL_WARN_OUT
6 (0x40)
REL_ERR_OUT
7 (0x80)
--
Command
Meaning
0
Confirmation of the last command
1
Perform pairing (activate tool monitoring)
74
Activate test mode
75
End test mode