18/40
Operating instructions EtherCatWPM Gateway Fieldbus
Operation
6.2
Configuration operation
The WPM Gateway does not need external configuration.
The EtherCAT communication and data are configured via PLC.
An EtherCAT XML file (device description file) is available for this purpose.
6.3
Normal operating modes
The WPM Gateway has four operating modes:
•
Simple digital I/O operation for systems without EtherCAT,
•
Pairing with tools
•
Fieldbus operation for complete integration into system control
•
The option of using WPM configuration software to access the radio interface directly
–
This function is currently deactivated
6.3.1
Normal digital I/O operation
For digital IO operation, there are 4 digital inlets, 4 digital outlets and 3 relays available.
6.3.1.1
Status information at digital outlets
Outlet signal
Status
Description
D0_OUT
Signal light is green,
status is ok.
On
All statuses of all connected
WPM pressure sensors are in order
Blinking
During active tool monitoring, at least one moni-
tored sensor did not receive any information for
a period exceeding 120 seconds
D1_OUT
Signal light is orange,
status is warning.
On
At least one connected WPM pressure sensor or
WPM data holder has a warning
D2_OUT
Signal light is red,
status is error.
On
At least one connected WPM pressure sensor or
WPM data holder has an alarm
D3_OUT
Signal light is blue,
Pairing
On
Connection successfully completed,
tool monitoring is active.
Blinking (1)
The gateway creates a connection with the
pressing tool and scans all the WPM compo-
nents connected to it
Blinking (2)
If D0_OUT is blinking:
During active tool monitoring, at least one moni-
tored sensor did not receive any information for
a period exceeding 120 seconds
Содержание 2480.00.91.40
Страница 34: ...34 40 Operating instructions EtherCatWPM Gateway Fieldbus Technical data 9 2 Technical drawing ...
Страница 37: ...Operating instructions EtherCatWPM Gateway Fieldbus 37 40 Appendix 11 APPENDIX 11 1 Personal notes ...
Страница 38: ...38 40 Operating instructions EtherCatWPM Gateway Fieldbus Appendix ...
Страница 39: ...Operating instructions EtherCatWPM Gateway Fieldbus 39 40 Appendix ...