Festo — YJKP-ST/MT — 2021-11f
Installation
25
Connection
Plug/cable
Purpose
[X4]
Connecting cable
NEBC-S1WA9-P-1.5-N-BB-L2G4
Connection for controller
CECC-X-M1-YS
[X6]
Motor cable
Connection for servo motor con-
nection
[X9]
Plug
1)
Power supply
[X18]
Standard LAN patch cable
2)
Ethernet interface
[X40]
Plug
1)
Interface for STO function
1) Plug for customer-provided cable
2) not included in the scope of delivery of the kit
Tab. 15: Connection and plug
Basic setting of DIP switch
The two DIP switches on the motor controller CMMP-AS must be set to a defined basic setting in this
application.
1. Set switch [S2] to the position [0].
2. Set switch [S3] to the position [0].
Power supply [X9]
•
Connect the power supply in accordance with the table
Force range
Power supply
Up to 4 kN
100 … 230 V AC (1 phase)
From 7 kN
230 … 480 V AC (3 phases)
Ethernet interface [X18]
The Ethernet interface is used to for the connection with the higher-order controller.
7.5
I/O interface for STO [X40]
The STO function is described in the additional documents
Motor controllers
Execution on the device
Mating plug
CMMP-AS
PHOENIX MINICOMBICON MC
1,5/8-GF-3,81 BK
PHOENIX MINICOMBICON MC
1,5/8-STF-3,81 BK
Tab. 16: Plug design [X40]