18
Festo — YJKP-ST/MT — 2021-11f
Installation
[X2, X3, X4] I/O ports
Terminal
Connection
Use
X2.0
…
X2.7
8 digital inputs
configurable as step enabling condition in the
sequencer of the press process: DI1
…
DI8
1)
X3.0
6 digital inputs
Start the press process
1)
Manual operating mode: plot the reference curve
Automatic mode: start press process
X3.1
"Manual" operating mode
1)
X3.2
“Automatic” operating mode
1)
X3.3
Start homing
1)
X3.4
Acknowledge error
1)
X3.5
Terminate press process
1)2)
X4.0
…
X4.3
4 digital outputs
configurable as output signals in the sequencer
of the press process: DO1
…
DO4
1)
24 V DC output that is set by the software as
soon as specific event occurs (position reached,
force reached).
X4.4
…
X4.7
not assigned
–
1) For details, see online help
2) Process termination if input = FALSE.
Tab. 11: [X2, X3, X4] I/O interface connections
[X8] Ethernet port
NOTICE
Unauthorised Access to the Device Can Cause Damage or Malfunction.
• When connecting the device to a network, protect the network from unauthorised access.
Standards for security in information technology can be used for network protection measures, e.g.
IEC 62443, ISO/IEC 27001.
The Ethernet port [X8] is a RJ45 socket and supports gigabit LAN.
The following protocols are supported:
–
EtherNet/IP (server)
–
Modbus TCP (server)
–
Ethernet TCP/IP
–
PROFINET IO
–
OPC UA (Only possible with the optional software extension package.)