Terminal
Connection
Use
X17.0.1
24 V DC
Power supply 24 V DC for program selection bit
0
1)
X17.0.2
Input DI9
Program selection bit 0
X17.0.3
GND logic
Power supply GND sensor for program selection
bit 0
1)
X17.1.1
24 V DC
Power supply 24 V DC sensor for program selec-
tion bit 1
1)
X17.1.2
Input DI10
Program selection bit 1
X17.1.3
GND logic
Power supply GND sensor for program selection
bit 1
1)
X17.2.1
24 V DC
Power supply 24 V DC sensor for program selec-
tion bit 2
1)
X17.2.2
Input DI11
Program selection bit 2
X17.2.3
GND logic
Power supply GND sensor for program selection
bit 2
1)
X17.3.1
24 V DC
Power supply 24 V DC sensor for program selec-
tion bit 3
1)
X17.3.2
Input DI12
Program selection bit 3
X17.3.3
GND logic
Power supply GND sensor for program selection
bit 3
1)
X17.4.1
24 V DC
Power supply 24 V DC
2)
X17.4.2
Servo press activation
Power stage enable motor controller via control
CECC-X-M1-YS
X17.4.3
GND logic
Power supply GND
2)
X17.5.1
24 V DC
Power supply 24 V DC
2)
X17.5.2
Activation of step oper-
ation
Press process in step operation
X17.5.3
GND logic
Power supply GND
2)
X17.6.1 … X17.6.3
not assigned
–
X17.7.1 … X17.7.3
not assigned
–
1) Optional
2) Reserve
Tab. 12: [X17] digital input terminal assignment