Festo — YJKP-ST/MT — 2021-11f
Installation
11
Sensor SKDA
Connecting cable NEBS-M12G5-ES-...-LE5
Controller
CECC-X-M1-YS
Pin
Wire colour
1)
Signal
Connection [X19]
3
BU
Input 4 … 20 mA
Evaluation of the sensor signal by
servo press software
X19.0.2
4
BK
not used
5
GY
not used
Shielding braid
Apply shielding braid in the direct
vicinity of the controller and sensor
with a large surface area
1) Colour code in accordance with IEC 60757:1983-01
Tab. 3: Sensor connecting cable - analogue inputs [X19]
1. Attach connecting cable to the sensor.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Partially remove the cable sheath on both sides and apply the shielding braid across a large
surface area with screening clamps
1
. Provide strain relief with cable binders
2
over the cable
outer sheath.
Sensor side
Controller side
1
2
2
1
4. Insert the plug into the connection [X19.0] of the controller.
Connecting cable NEBC-S1WA9-P-1.5-N-BB-L2G4
The connecting cable connects the CANopen interface [X4] of the motor controller to the CANopen
interface [X18] of the controller CECC-X-M1-YS.