Runtime performance
t1
>
5 ms:
Level of EN2/EN1 must be HIGH for min. 5 ms (debounce time/input filter/stabil-
isation time).
t2
<
= 75 ms:
maximum permissible delay time between EN1 and EN2. If exceeded, the product
is not pressurised and an error message is output.
t3
>
= 15 ms:
Level of EN2/EN1 must be LOW for min. 15 ms (debounce time/input filter/sta-
bilisation time).
t4 = 2 ms:
maximum internal time delay caused by the program sequence.
tp1
}
2:
Pressurisation
>
300 ms
tp2
}
3:
Exhausting
>
1 s
Tab. 14 Runtime performance
14.7.2
Switching characteristics for multi-pin plug socket NECA-S1G9-P9-MP3/-MP5
1 Operating pressure p1
2 Outlet pressure p2
3 +L1: operating voltage
4 EN1: Enable signal 1
5 EN2: Enable signal 2
6 Signal contacts
7 Power LED (green)
8 Error LED (red)
Fig. 23 Input and output switching characteristics in normal operation (when automatic start mode of
operation is set) for multi-pin plug socket NECA-S1G9-P9-MP3/-MP5
Technical Data
35