PFH
d
value
The PFH
d
value depends on the model of the product and the annual actuation rate (n
op
).
1 PFH
d
[10
-8
h
-1
]
2 Actuation rate (n
op
) [10
4
/a]
Fig. 12 PFHd value
6
Assembly
6.1
Requirement
–
Take appropriate measures to remove any particles in the supply lines.
6.2
Preparation
NOTICE!
In order to ensure electromagnetic compatibility in accordance with the EMC Directive, note the follow-
ing:
•
Ensure a wall clearance of 32 mm, e.g. with the MS6-WPB mounting bracket.
•
Do not lay cables between the wall and the product.
NOTICE!
Failure of the safety function.
Failure to comply with the minimum distance of 15 mm between the silencer and base can result in
the loss of the safety function.
•
Observe minimum distance of 15 mm below the silencer .
The free space ensures the exhaust can escape.
–
Place product as close as possible to the installation site.
–
The product can be mounted in any position.
Assembly
17
Festo — MS6-SV-...-E-10V24 — 2019-10d