MS6-SV-E
Medium
Operating medium
Compressed air according to ISO 8573-1:2010 [7:4:4]
and inert gases
Note
Lubricated operation possible, in which case lubric-
ated operation will always be required
Temperature
Medium
[
°
C]
-10
…
+50
Environment
[
°
C]
-10
…
+50
Bearing
[
°
C]
-10
…
+50
Operating pressure
Operating pressure
[bar]
3.5
…
10
Residual pressure in normal
operation
[bar]
0 (no residual pressure)
Residual pressure in the event
of error
[bar]
£
0.4 (at p1 = 10 bar and flow control fully open)
C value
[l/(s bar)] 19.3
B value
0.21
Flow rate values
Standard nominal flow rate
1
}
2
[l/min]
4300 (at p1 = 6 bar, p2 = 5 bar)
Standard flow rate 2
}
3
[l/min]
9000 (at p1 = 6 bar
Standard flow rate 2
}
3 in the
event of a critical fault
[l/min]
³
6000 (at p1 = 6 bar)
Switch-through point
Approx. 50% of p1
Filling flow
Adjustable by flow control
minimum pause time after
exhaust
[s]
³
2
Tab. 10 Technical Data, Pneumatic
14.3
Technical Data, Electrical
MS6-SV-E
Actuation type
Electrical
Switching frequency
[Hz]
£
0.5
Technical Data
28
Festo — MS6-SV-...-E-10V24 — 2019-10d