Fig. 9 Static enable signals – signal distance
Switching characteristics diagrams
è
Switching statuses
The time delay t2 between EN1 and EN2 must be automatically defined. The duration of the delay is
not evaluated. The multi-pin plug socket NECA-MP5 does not enable the product to detect shorts
across contacts.
Signal contact
The signal contact is a potential-free N/O contact of a semiconductor relay. The contact can be picked
up in the feedback circuit of a safety control system through terminals 3 and 4 of the NECA multi-pin
plug socket as required.
NOTICE!
If the signal contact is operated outside the permitted technical data, this will cause irreparable fail-
ure. Compliance with the specification must be ensured through an appropriate protective circuit.
NOTICE!
Assignment of these contacts is not required to achieve the safety category.
Fig. 10 Feedback signal connection