A
Technical appendix
Festo – P.BE-MPA-EN – 1309f – English
139
The fittings of the pneumatic ports cause a reduction in the nominal flow rate of the
valves.
Standard nominal flow rates MPA1 (width 10 mm)
Ident. code
1)
Valve
Standard nominal flow rates [I/min], measured with
fitting QS-M7-6-I
1
}
2 or 1
}
4
2)
2
}
3/5 or 4
}
3/5
2)
M, MS, J
5/2-way
360
360
MU
5/2-way
190 (1
}
2)/160 (1
}
4)
190 (2
}
3)/160 (4
}
5)
B
5/3-way, pressurized
300 (220)
3)
270
G
5/3-way, closed
320
320
E
5/3-way, exhausted
240
240 (200)
3)
H
2x 3/2-way
300
300
HS
2x 3/2-way
300
305
K, KS
2x 3/2-way
230
310
N, NS
2x 3/2-way
300
300
KU
2x 3/2-way
160
170
NU
2x 3/2-way
190
160
HU
2x 3/2-way
190 (1
}
2)/160 (1
}
4)
160 (2
}
3)/170 (4
}
5)
W, X
1x 3/2-way
255
295
D, DS
2x 2/2-way
230
—
I
2x 2/2-way
260
260
1)
Ident. code of the valve sub-base
2)
Flow direction 1
}
4 or 4
}
3/5 not with valves having ident. codes I, W and X
3)
Values for the mid-position are specified in brackets
Tab. A.7
Technical data: nominal flow rates MPA1