5
Conversion and maintenance
100
Festo – P.BE-MPA-EN – 1309f – English
5.1
General instructions
Information on the delivery status of your valve terminal can be found using the product
key (
section A.1.5).
Warning
Uncontrolled movements of the connected actuator technology and loose tubing can
cause injury to persons and/or damage to property.
•
Before carrying out installation and maintenance work, switch off the following:
–
Compressed air supply
–
Operating and load voltage supply.
Note
•
Handle all modules and components of the MPA-S valve terminal with care.
•
Note especially the following when mounting components:
–
Position screws exactly before tightening (otherwise their threads may be dam-
aged).
–
Screws should only be tightened by hand. Screws must be placed so that the
self-cutting threads can be used.
–
The specified torques must be observed.
–
Threaded fittings must be free of distortion and mechanical tension.
–
Check the seals for damage (IP 65).
–
The contact surfaces must be dry and clean (sealing effect, avoidance of leakage
and contact errors).