A
Technical appendix
Festo – P.BE-MPA-EN – 1309f – English
135
A.1.3
Pneumatics
Solenoid valves
Operating/pilot medium
Compressed air in accordance with ISO
8573-1:2010 [7:4:4]
Notes on the operating/pilot medium
Lubricated operation possible (in which case
lubricated operation will always be required)
Design
–
Valve sub-bases with piston spool valves
–
Valve sub-bases with poppet valves
Manual override
Non-detenting or turning with detent
Operating pressure/pilot pressure
–
Valves with
internal pilot air supply
(branched from connection (1))
All valve sub-bases on port (1)
The pressure at the connection (1) must lie within
the range of the required pilot pressure of the
valves. (
diagrams Fig. A.1 … Fig. A.5, max. 8 bar)
–
Valves with
external pilot air supply
Valve position Ident code B, E, G, J and
M at port (1)
–0.9 … 10 bar
Valve position Ident. code DS, HS, KS,
MS and NS at port (1)
–0.9 … 8 bar
Valve position Ident. code W at port (2)
–0.9 … 10 bar
Valve position Ident. code X at port (4)
–0.9 … 10 bar
Valve position Ident. code D, H, I, K and
N at port (1)
3 … 10 bar
Valve position Ident. code MU, NU, KU,
and HU at port (1)
–0.9 … 10 bar
All valve sub-bases at port (12/14)
Diagrams Fig. A.1 … Fig. A.5, pressure P2
(max. 8 bar)
Tab. A.6
Technical data: solenoid valves
Содержание MPA-S