![Festo CPX-AP-I-4IOL-M12 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/festo/cpx-ap-i-4iol-m12/cpx-ap-i-4iol-m12_instructions-manual_2283157013.webp)
AP parameter
ID
Parameter
Instance-
s
Data
type
Access
1)
Arraysize
246
Fieldbus serial number
1
UINT32
ro
–
791
Product key
1
CHAR
ro
12
960
Firmware version
1
CHAR
ro
40
20000
Module code
1
UINT32
ro
–
20085
Measured value temperature AP-ASIC [°C]
1
INT16
ro
–
20087
Current measured value of logic supply PS
[mV]
1
UINT16
ro
–
20088
Current measured value of load supply PL
[mV]
1
UINT16
ro
–
20090
IO-Link variant
–
8201: variant 8 (factory setting)
–
8205: variant 8 OE
–
8206: variant 2
–
8207: variant 2 OE
–
8208: variant 4
–
8209: variant 4 OE
–
8210: variant 16
–
8211: variant 16 OE
–
8212: variant 32
–
8213: variant 32 OE
1
UINT16
rw
–
20093
Hardware version
1
UINT8
ro
–
20097
Activation of the sensor supply
(factory setting TRUE)
1
BOOL
rw
–
1) ro = read only; rw = read write
Tab. 13 AP parameter
10
Diagnostics and fault clearance
10.1
Diagnostic messages
Diagnostic messages of an IO-Link device are sent to the IO-Link master via event codes. The event
code is mapped in the IO-Link master to a diagnostics ID
è
Information on grouping and displaying the diagnostic messages
è
Instruction manual for the auto-
mation system CPX-AP.
Diagnostics and fault clearance
13
Festo — CPX-AP-I-4IOL-M12 — 2020-03