ID
Parameter
Instance-
s
Data
type
Access
1)
Arraysize
20080
Setpoint device ID
2)
4
UINT32
rw
–
1) ro = read only; rw = read write
2) Changes only become effective when the port mode is changed (ID 20071).
3) Only supported in combination with IO-Link V1.1 devices.
Tab. 11 Fieldbus startup parameters
Fieldbus parameters (status/information)
ID
Parameter
Instance-
s
Data
type
Access
1)
Arraysize
20074
Port status information
–
0: NO_DEVICE (factory setting)
–
1: DEACTIVATED
–
2: PORT_DIAG
–
3: PREOPERATE
–
4: OPERATE
–
5: DI_CQ
–
6: DO_CQ
–
254: PORT_POWER_OFF
–
255: NOT_AVAILABLE
4
UINT8
ro
–
20075
Revision ID
4
UINT8
ro
–
20076
Transmission rate
–
0: Not detected
–
1: COM1
–
2: COM2
–
3: COM3
4
UINT8
ro
–
20077
Actual cycle time [in 100 µs]
4
UINT16
ro
–
20078
Actual vendor ID
4
UINT16
ro
–
20079
Actual device ID
4
UINT32
ro
–
20108
Input data length
4
UINT8
ro
–
20109
Output data length
4
UINT8
ro
–
1) ro = read only; rw = read write
Tab. 12 Fieldbus parameters (status/information)
Parameterisation
12
Festo — CPX-AP-I-4IOL-M12 — 2020-03