Important instructions

Definition of individual target groups

Project engineers for safe drive systems

engineers and technicians

Mounting, electrical installation, maintenance and device replacement:

company electricians and service technicians

Commissioning, operation and configuration:

technicians and engineers

2

Safety instructions

2.1

Installation and commissioning

Never install damaged products or place them in operation. Report damages immediately to the

responsible forwarding agent.

Installation, commissioning and service work on the device may only be performed by trained elec-

tricians with knowledge of the relevant accident prevention regulations.

The applicable regulations and other special safety regulations for the item and application must be

observed.

2.2

User instructions

Install and place the module in operation only if you are aware of the applicable regulations for

industrial safety and the operating instructions for the CMGA-B1 basic modules!

2.3

Intended utilization

The module may only be used in a PROFIBUS-DP environment as a “SLAVE” sub-assembly in accord-

ance with the standard EN 50170.

CMGA-E1-PB must not be used for safety-relevant reactions.

2.4

Operation and service

Before installation and removal of the module or disconnecting signal and power supply cables,

power to the module must be switched off.

During installation and removal of the module, appropriate measures must be applied to prevent

electrostatic discharge to the externally arranged terminal and plug connections.

Содержание CMGA-E1-PB

Страница 1: ...Description Installation manual Extension module PROFIBUS 761722 1201NH Extension module CMGA E1 PB...

Страница 2: ...Dangers that can result in death or serious injuries Caution Dangers that can result in light injuries or serious material damage Other symbols Note Material damage or loss of function Recommendation...

Страница 3: ...6 4 2 Linking of the GSD file 6 4 2 1 Installation of the GSD file 6 4 2 2 Link to network diagram Step7 7 4 2 3 Link to Hardware Config 7 4 2 4 Configuration CMGA E1 PB 8 4 2 5 Configuration of CAN...

Страница 4: ...nt prevention regulations The applicable regulations and other special safety regulations for the item and application must be observed 2 2 User instructions Install and place the module in operation...

Страница 5: ...0 through PROFIBUS DP A maximum of 8 CAN telegrams can be received and passed on The module must be parametrised as a Profibus station slave The PROFIBUS baud rate of 9 6 kBaud to 12 Mbaud is recognis...

Страница 6: ...sonnel Strictly observe the safety instructions when commissioning In the following commissioning in Step7 is shown as an example 4 2 Linking of the GSD file First copy the GSD file and the dib files...

Страница 7: ...em Additional field devices General CMGA E1 PB drag DP V0 into the network dia gram and assign Profibus address Fig 4 Netpro 4 2 3 Link to Hardware Config CMGA E1 PB Select module and fill card slot w...

Страница 8: ...EN 1201NH Fig 5 Hardware Config insert input 8 byte 4 2 4 Configuration CMGA E1 PB The following displays the configurations that are needed for the internal CAN bus backwall bus of the CMGA safety s...

Страница 9: ...of diagnostics in the programming manual Tab 1 Settings for DP slave Note Only when connected to the PROFIBUS master system are the configured data accep ted into the CMGA E1 PB Otherwise the default...

Страница 10: ...Terminating resistors for CAN bus connection Coding switch Description 1 2 ON Switch 1 120 ohm terminating resistor on backwall of CAN Switch 2 120 ohm terminating resistor 2nd CAN interface via SUB...

Страница 11: ...e 5 1 Replacement of a module Note Plug in connections of the CMGA module must not be disconnected or reconnected when powered There is a danger of sensor damage particularly with connected posi tion...

Страница 12: ...t temperature Tab 7 Technical data environmental conditions 6 2 Characteristic data Extension module CMGA E1 PB System run time 20 ms Number of CAN objects 1 to 8 Size of CAN telegrams 8 bytes CAN ID...

Страница 13: ...CMGA E1 PB Festo GDCP CMGA E1 PB EN 1201NH 13...

Страница 14: ...CMGA E1 PB 14 Festo GDCP CMGA E1 PB EN 1201NH...

Страница 15: ...CMGA E1 PB Festo GDCP CMGA E1 PB EN 1201NH 15...

Страница 16: ...t express authorization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Postfach...

Отзывы: