CMGA-E1-PB
10
Festo – GDCP-CMGA-E1-PB-EN – 1201NH
4.3
Device settings
The following can be set on the front side of the module:
1
Coding switch, bus
termination
2
Diagnostics LEDs
3
PROFIBUS plug connector
4
PROFIBUS address switch
1
2
3
4
Fig. 8
Front CMGA-E1-PB
4.3.1
Address wheels
Input of the Profibus address in hexadecimal.
Example address
Hexadecimal
ADDR HIGH
ADDR LOW
5
05
0
5
46
2E
2
I
Tab. 4
PROFIBUS address
4.3.2
Coding switch
Terminating resistors for CAN bus connection:
Coding switch
Description
1
2
ON
Switch 1
120 ohm terminating resistor on backwall of CAN
Switch 2
120 ohm terminating resistor 2nd CAN-interface via SUB-D socket
Tab. 5
Coding switch, terminating resistors
4.4
Diagnostics
LED
Colour
Mode
Description
RUN
Green
“Flashing”
Module OK
DP
Green
“Permanent”
Profibus connection active
Green
“Flashing”
Profibus connection interrupted
Red
“Flashing”
Transferred parameter data invalid
XB
Green
“Flashing”
“Internal” CAN telegram (CMGA) is being received
Red
“Flashing”
Missing CAN telegram or CAN telegram not within the
“CAN WD Timeout” time
Tab. 6
LED display
Содержание CMGA-E1-PB
Страница 1: ...Description Installation manual Extension module PROFIBUS 761722 1201NH Extension module CMGA E1 PB...
Страница 13: ...CMGA E1 PB Festo GDCP CMGA E1 PB EN 1201NH 13...
Страница 14: ...CMGA E1 PB 14 Festo GDCP CMGA E1 PB EN 1201NH...
Страница 15: ...CMGA E1 PB Festo GDCP CMGA E1 PB EN 1201NH 15...