81
65
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
7
kW
Seasonal space heating
energy efficiency
ηs
106
%
Tj = -7
℃
Pdh
4.4
kW
Tj = -7
℃
COPd
2.26
-
Tj = 2
℃
Pdh
2.5
kW
Tj = 2
℃
COPd
3.43
-
Tj = 7
℃
Pdh
1.6
kW
Tj = 7
℃
COPd
4.39
-
Tj = 12
℃
Pdh
1.0
kW
Tj = 12
℃
COPd
5.39
-
Tj = bivalent temperature
Pdh
5.4
kW
Tj = bivalent temperature
COPd
1.77
-
Tj = operating limit
Pdh
4.2
kW
Tj = operating limit
COPd
1.34
-
For air-to-water heat pumps:
Tj = -15
℃
Pdh
5.0
kW
For air-to-water heat pumps:
Tj = -15
℃
COPd
1.66
-
Bivalent temperature
T
biv
-13
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-20
°C
Cycling interval capacity for
heating
P
cych
-
kW
Cycling interval efficiency
COP
cyc
or
PERcyc
-
%
Degradation co-efficient (**)
C
dh
0.9
--
Heating water operating limit
temperature
W
TOL
40
°C
off mode
P
off
0.016
kW
standby mode
P
sb
0.016
kW
thermostat-off mode
P
to
0.016
kW
crankcase heater mode
P
ck
0.034
kW
Sound power level, indoors/
outdoors
L
WA
-/65
dB
Annual energy consumption
Q
HE
6436
kWh
or GJ
Declared load profile
Water heating energy
efficiency
η
wh
-
%
Daily electricity consumption
Q
elec
-
kWh
Daily fuel consumption
Q
fuel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
Contact details
7
YES
NO
NO
NO
NO
NO
Model(s):
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Type of energy input
-
Rated heat output (**)
2.5
Psup
kW
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
_
-
m
3
/h
_
3050
m³/h
Technical parameters
variable
Capacity control
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters
shall be declared for low-temperature application.
Air-to-water heat pump:
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Power consumption in modes other than active mode
Supplementary heater
-
For heat pump combination heater:
For air-to-water heat pumps:
Rated air flow rate, outdoors
Parameters shall be declared for average, colder and warmer climate conditions
Other items
66
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
7
kW
Seasonal space heating
energy efficiency
ηs
167
%
Tj = -7
℃
Pdh
-
kW
Tj = -7
℃
COPd
-
-
Tj = 2
℃
Pdh
6.8
kW
Tj = 2
℃
COPd
2.18
-
Tj = 7
℃
Pdh
4.4
kW
Tj = 7
℃
COPd
3.45
-
Tj = 12
℃
Pdh
2.1
kW
Tj = 12
℃
COPd
6.01
-
Tj = bivalent temperature
Pdh
4.4
kW
Tj = bivalent temperature
COPd
3.45
-
Tj = operating limit
Pdh
6.8
kW
Tj = operating limit
COPd
2.18
-
For air-to-water heat pumps:
Tj = -15
℃
Pdh
-
kW
For air-to-water heat pumps:
Tj = -15
℃
COPd
-
-
Bivalent temperature
T
biv
7
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
2
°C
Cycling interval capacity for
heating
P
cych
-
kW
Cycling interval efficiency
COP
cyc
or
PERcyc
-
%
Degradation co-efficient (**)
C
dh
0.9
--
Heating water operating limit
temperature
W
TOL
60
°C
off mode
P
off
0.016
kW
standby mode
P
sb
0.016
kW
thermostat-off mode
P
to
0.016
kW
crankcase heater mode
P
ck
0.034
kW
Sound power level, indoors/
outdoors
L
WA
-/65
dB
Annual energy consumption
Q
HE
2121
kWh
or GJ
Declared load profile
Water heating energy
efficiency
η
wh
-
%
Daily electricity consumption
Q
elec
-
kWh
Daily fuel consumption
Q
fuel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
Contact details
7
YES
NO
NO
NO
NO
NO
Model(s):
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Type of energy input
-
Rated heat output (**)
0
Psup
kW
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
_
-
m
3
/h
_
3050
m³/h
Technical parameters
variable
Capacity control
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters
shall be declared for low-temperature application.
Air-to-water heat pump:
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Power consumption in modes other than active mode
Supplementary heater
-
For heat pump combination heater:
For air-to-water heat pumps:
Rated air flow rate, outdoors
Parameters shall be declared for average, colder and warmer climate conditions
Other items
ERP DATA
RVL-I PLUS 7 - Warmer climate condition
Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A - tel . +39 .045 .6139411 ¬ fax +39 .045 .6100933 ¬ www .ferroli .com
Содержание RVL-I PLUS
Страница 31: ...31 SETUP OF THE SYSTEM...
Страница 32: ...32 SETUP OF THE SYSTEM...
Страница 33: ...33 SETUP OF THE SYSTEM...
Страница 34: ...34 SETUP OF THE SYSTEM FOR SEVICEMAN menu english language...
Страница 35: ...35 SETUP OF THE SYSTEM...
Страница 36: ...36 SETUP OF THE SYSTEM...
Страница 37: ...37 SETUP OF THE SYSTEM...
Страница 91: ...91...