SETUP OF THE SYSTEM
When the cursor is on OPERATE PREHEATING FOR FLOOR, Use ◄ ► to scroll to
YES and press OK . The page will be displayed as follows:
During preheating for floor, all the buttons except OK are invalid. If you want to turn off
the preheating for floor, please press OK. The following page will be displayed:
Use ◄ ►to scroll the cursor to YES and press OK, the preheating for floor will turn off.
Before floor heating, if large a amount of water remains on the floor, the floor may be
warped or even rupture during floor heating operation, in order to protect the floor, floor
drying is necessary, during which the temperature of the floor should be increased
gradually .
If FLOOR DRYING UP is selected, after press OK ,the page will displayed as follows:
When the cursor is on OPERATE FLOOR DRYING? Use ◄ ► to scroll to YES and
press OK . The page will be displayed as follows:
During floor drying, all the buttons except OK are invalid. When the heat pump mal-
functions, the floor drying mode will turn off when the backup heater and additional
heating source is unavailable. If you want to turn off floor drying up, please press OK.
The following page will be displayed:
Use ◄ ► to scroll the cursor to YES and press OK. Floor drying will turn off.
When the cursor is on WARM UP TIME (t_DRYUP), KEEP
TIME (t_HIGHPEAK), TEMP . DOWN TIME (t_DRYD), PEAK
TEMP . (T_DRYPEAK), START TIME or START DATA, Use
◄ ► and ▼ ▲ to scroll and adjust the parameter.
t_DRYUP is the day for warming up .
t_HIGHPEAK is the last day of high temperature .
t_DRYD is the day of dropping temperature
T_DRYPEAK is the target peak temperature of water flow
during floor drying up.
The target outlet water temperature during floor drying up
described
in the picture below:
13.2 PREHEATING FOR FLOOR
Preheat for floor is
running for 25 minutes.
Water flow temperature is 20
°C.
CONFIRM
OK
13.2 PREHEATING FOR FLOOR
Do you want to turn of the
preheating for floor function?
SCROLL
CONFIRM
OK
NO
YES
13.3 FLOOR DRYING UP
WARM UP TIME(t_DRYUP)
KEEP TIME(t HIGHPEAK)
PEAK TEMP. (T_DRYPEAK)
START TIME
START DATE
8 days
5 days
45°C
15:00
01-05-2015
SCROLL
1/2
t_DRYUP t_DRYPEAK
T1S
t
t_DRYD
T_DRYPEAK
13.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
CONFIRM
OK
Use ▼, ▲, ◄, ► to scroll and use OK to select YES or NON to enable or disable
the auto restart function . If the auto restart function is enabled, when power returns
after a power supply failure, the AUTO RESTART function reapplies the user interface
settings at the time of the power supply failure . If this function is disabled, when power
returns after a power supply failure, the unit won’t auto restart .
Auto restart
The AUTO RESTART function is used to select whether the unit reapplies the user interface settings at the time when power
returns after a power supply .
Go to MENU> FOR SERVICEMAN> AUTO RESTART
14 AUTO RESTART
DHW MODE
COOL/HEAT MODE
SCROLL
YES
YES
NO
NO
Содержание RVL-I PLUS
Страница 31: ...31 SETUP OF THE SYSTEM...
Страница 32: ...32 SETUP OF THE SYSTEM...
Страница 33: ...33 SETUP OF THE SYSTEM...
Страница 34: ...34 SETUP OF THE SYSTEM FOR SEVICEMAN menu english language...
Страница 35: ...35 SETUP OF THE SYSTEM...
Страница 36: ...36 SETUP OF THE SYSTEM...
Страница 37: ...37 SETUP OF THE SYSTEM...
Страница 91: ...91...