6
Presentation of the unit
This series of air-water heat pumps meets the needs of winter and summer air conditioning of residential and commercial installations
of small and medium power.
All units are suitable for outdoor installation and being able to produce water up to 60 ° C may be employed in systems with radiant floor,
fancoils, radiators and for the indirect production of domestic hot water (DHW) via an external boiler (not provided).
The units are characterized by the use of a DC inverter compressor that allows you to modulate the capacity from 30 to 120% of the rated
capacity and are complete with a hydronic kit including all the essential components for a quick and safe installation.
The units are characterized by high energy efficiency and low noise level and they can be used as the sole generator of the system or
integrated with other energy sources such as backup electric heaters or boiler.
All units are supplied with temperature probe (included) for domestic hot water tank (DHW) and with external air temperature probe
(already installed on the unit) to realize the climatic control in heating and cooling modes.
All the units are accurately built and individually tested in the factory. The installation only requires the electrical and hydraulic connections.
Model
Power supply
Unit
-
- 230 V - 1 - 50 Hz
T
- 400 V - 3N - 50 Hz
5
7
10
14
Unit identification code
The codes that identify the units and the meaning of the letters used are described below .
Codice
Code
B1
Rev
Ferroli Spa
Via Ritonda 78/A
(VR) Italy
Codice
Code
B1
Rev
Ferroli Spa
Via Ritonda 78/A
(VR) Italy
Identification plate of the Unit
The figure on the left depicts the identification plate of the unit, affixed to the outer left-hand side of the Electric Panel . A description of the data is given below:
CASE 1
CASE 2
A -
Trademark
B -
Model
B1-
Code
C -
Serial number
D -
Cooling Capacity
E -
Heating Capacity
F -
Power input in COOLING mode
G -
Power input in HEATING mode
H -
Reference standard
I -
Electric power supply
L -
Maximum load current
M -
Type of refrigerant and charge
N -
Shipping weight of the unit
O -
Sound pressure level at 1m
P -
IP Level Protection
Q -
Maximum pressure - High Side
R -
Maximum pressure - Low Side
S -
PED certification authority
C
European Directives
The company hereby declares that the machine in question complies with the matters prescribed by the following Directives:
• Low voltage directive 2014/35/EU
• Electromagnetic Compatibility directive 2014/30/EU
• ERP directive 2009/125/EC (EU) No 811/2013 (EU) No 813/2013
• Energy
labelling directive 2010/30/UE
• WEE directive 2002/96/EC
• RoHS directive 2011/65/EU
• REACH (EC) European regulation No 1907/2006
Any other Directives have to be considered not applicable .
GENERAL FEATURES
-
RVL-I PLUS 14 T
Содержание RVL-I PLUS
Страница 31: ...31 SETUP OF THE SYSTEM...
Страница 32: ...32 SETUP OF THE SYSTEM...
Страница 33: ...33 SETUP OF THE SYSTEM...
Страница 34: ...34 SETUP OF THE SYSTEM FOR SEVICEMAN menu english language...
Страница 35: ...35 SETUP OF THE SYSTEM...
Страница 36: ...36 SETUP OF THE SYSTEM...
Страница 37: ...37 SETUP OF THE SYSTEM...
Страница 91: ...91...