Connection with separate pipes
fig. 15 - Examples of connection with separate pipes (
= Air /
= Fumes)
Table. 4 - Typology
For connection of the separate ducts, fit the unit with the following starting accessory:
fig. 16 - Starting accessory for separate ducts
Before installation, check the baffle to be used and make sure the maximum permissible
length has not been exceeded, by means of a simple calculation:
1.
Completely establish the layout of the system of split flues, including accessories
and outlet terminals.
2.
Consult the table 6 and identify the losses in m
eq
(equivalent metres) of every com-
ponent, according to the installation position.
3.
Check that the sum total of losses is less than or equal to the maximum permissible
length in table 5.
Table. 5 - Baffles for separate ducts
Table. 6 - Accessories
Position of terminals
fig. 17
Connection to multiple flues or single flues with natural draught
To connect the
DOMIcondens HE 26 C
boiler to a multiple flue or a single flue with nat-
ural draught, the flue or chimney must be expressly designed by professionally qualified
technical personnel in conformity with the current standards and regulations.
In particular, flues and chimneys must:
•
Be sized according to the method of calculation given in the standard.
•
Be tight with respect to the products of combustion, resistant to the fumes and heat
and impermeable to condensate.
•
Have a circular or square cross-section (some hydraulically equivalent sections are
permissible), with a vertical progression and with no constrictions.
•
Have the ducts conveying the hot fumes at a suitable distance or separately from
combustible materials.
•
Be connected to just one unit per floor, for not more than 6 units (8 if there is a com-
pensation duct or opening).
•
Have no mechanical suction devices in the main ducts.
•
Be at low pressure, all along their length, in conditions of stationary operation.
•
Have at their base a collection chamber for solid materials or condensate, of at least
0.5 m, equipped with an airtight metal door.
Type
Description
C1X
Wall horizontal exhaust and intake. The inlet/outlet terminals must be concentric or close enough to be
undergo similar wind conditions (within 50 cm)
C3X
Roof vertical exhaust and intake. Inlet/outlet terminals like for C12
C5X
Wall or roof exhaust and intake separate or in any case in areas with different pressures. The exhaust
and intake must not be positioned on opposite walls.
C6X
Intake and exhaust with separately certified pipes (EN 1856/1)
B2X
Intake from installation room and wall or roof exhaust
IMPORTANT - THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
Separate ducts
Max. permissible length
55 m
eq
Baffle to use
0 ÷ 15 m
eq
Ø 45
15 ÷ 35 m
eq
Ø 50
35 ÷ 55 m
eq
No baffle
Losses in m
eq
Air
inlet
Fume exhaust
Vertical
Horizontal
Ø 80
PIPE
1 m M/F
1KWMA83W
1.0
1.6
2.0
BEND
45° M/F
1KWMA65W
1.2
1.8
90° M/F
1KWMA01W
1,5
2.0
PIPE SECTION
with test point
1KWMA70W
0.3
0.3
TERMINAL
air, wall
1KWMA85A
2.0
-
fumes, wall with antiwind
1KWMA86A
-
5.0
FLUE
Split air/fumes 80/80
010027X0
-
12.0
Fume outlet only Ø80
01
1KWMA86U
-
4.0
Ø 60
PIPE
1 m M/F
1KWMA89W
6.0
BEND
90° M/F
1KWMA88W
4.5
REDUCTION
80/60
041050X0
5.0
TERMINAL
fumes, wall with antiwind
1KWMA90A
7.0
ATTENTION: CONSIDER THE HIGH PRESSURE LOSSES OF Ø60 ACCESSORIES;
USE THEM ONLY IF NECESSARY AND AT THE LAST FUME EXHAUST SECTION.
C
5x
C
3x
B
2x
C
1x
max 50 cm
Ø 81
Ø 81
Ø
65
Ø
87
Ø
65
041039X0
Minimum dimensions of fume exhaust terminals
A
Directly under an opening, air inlet,
openable window, etc.
300 mm
B
Above an opening, air inlet, openable
window, etc.
300 mm
C
Horizontally to an opening, air inlet,
openable window, etc.
300 mm
D
Under gutters, drain pipes
75 mm
E
Under cornices or under eaves
200 mm
F
Under balconies or garages
200 mm
G
From a drain pipe or a vertical drain
pipe
150 mm
H
From an internal or external corner
100 mm
I
Above ground level, a roof or balcony
300 mm
J
From a surface facing the terminal
600 mm
K
From a terminal facing the terminal
1200 mm
litres
From a garage opening (e.g. door,
window) with access to the home
1200 mm
M
Vertically from a terminal on the same
wall
1500 mm
No
Horizontally from a terminal on the
same wall
300 mm
O
From the wall on which the terminal is
fitted
N/A
P
From a vertical structure on the roof
150 mm
Q
Above the intersection with the roof
300 mm
NOTES
•
N/A = Not applicable
•
Also, the terminal must be at least 150 mm (in case of forced intake)
from an opening made in the structure of the building to house a fitted
element such as a window frame.
•
Positions of condensate drain terminals: if the fume exhaust is pro-
vided for at a low level, the potential effect of the flue gas cloud must
be considered. Special flue gas management kits are available by
request.
•
The flue gas cloud must not be directed towards:
-
A frequented approach
-
A window or door
-
An adjacent property
P
D, E
Q
Q
l
B
C
A
G
F
L
J
H
H
K
N
N
M
M
Q
Содержание DOMIcondens HE 26 C
Страница 13: ......