DOMIcondens HE 26 C

3

EN

cod. 3540Z852  -  Rev. 01 - 08/2012

EN

1. GENERAL WARNINGS

Carefully read and follow the instructions contained in this instruction booklet.

After boiler installation, inform the user regarding its operation and give him this manual, which is
an integral and essential part of the product and must be kept with care for future reference.

Installation and maintenance must be carried out by professionally qualified personnel, in compli-
ance with the current regulations and according to the manufacturer's instructions. Do not carry
out any operation on the sealed control parts.

Incorrect installation or inadequate maintenance can result in damage or injury. The Manufacturer
declines any liability for damage due to errors in installation and use, or failure to follow the in-
structions.

Before carrying out any cleaning or maintenance operation, disconnect the unit from the electrical
power supply using the switch and/or the special cut-off devices.

In case of a fault and/or poor operation, deactivate the unit and do not try to repair it or directly
intervene. Contact professionally qualified personnel. Any repair/replacement of the products
must only be carried out by qualified personnel using original replacement parts. Failure to comply
with the above could affect the safety of the unit.

This unit must only be used for its intended purpose. Any other use is deemed improper and there-
fore hazardous.

The packing materials are potentially hazardous and must not be left within the reach of children.

The unit must not be used by people (including children) with limited physical, sensory or mental
abilities or without experience and knowledge of it, unless instructed or supervised in its use by
someone responsible for their safety.

The unit and its accessories must be appropriately disposed of, in compliance with the current reg-
ulations.

The images given in this manual are a simplified representation of the product. In this represen-
tation there may be slight and insignificant differences with respect to the product supplied.

2. OPERATING INSTRUCTIONS
2.1 Introduction

Dear Customer,

DOMIcondens HE 26 C

 is a high-efficiency sealed chamber

 condensing

 heat genera-

tor for heating and hot water production running on natural gas or LPG, and equipped
with a microprocessor control system.

2.2 Control panel
Panel

fig. 1 - Control panel

Panel key fig. 1
1

DHW temperature setting decrease button

2

DHW temperature setting increase button

3

Heating system temperature setting decrease button

4

Heating system temperature setting increase button

5

Display

6

"Sliding Temperature" Menu - Summer/Winter mode selection - Reset button

7

Unit On/Off - Economy/Comfort mode selection button

8

DHW symbol

9

DHW mode

10

Summer mode

11

Multifunction

12

Eco (Economy) mode

13

Heating

14

Heating symbol

15

Burner lit and actual power level (flashing during combustion fault function)

16

Service Tool connection

17

Arrangement for clock

Indication during operation
Heating

A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
The display (detail 11 - fig. 1) shows the actual heating delivery temperature and, during
heating standby time, the message 

“d2”

.

Domestic hot water (DHW)

A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during
DHW standby time, the message 

“d1“

.

Comfort

A Comfort demand (reinstatement of temperature inside the boiler) is indicated by flash-
ing of the water under the tap on the display. The display (detail 11 - fig. 1) shows the
actual temperature of the water in the boiler.

Fault

In case of a fault (see cap. 4.4) the display shows the fault code (detail 11 - fig. 1) and,
during safety standby times, the messages 

"d3"

 and 

"d4"

.

2.3 Lighting and turning off
Connection to the power supply

During the first 5 seconds the display will also show the card software release.

Open the gas cock ahead of the boiler.

The boiler is now ready to function automatically whenever domestic hot water is
drawn or in case of a heating demand (generated by Room Thermostat or Remote
Temperature Control).

Turning the boiler off and on

Press the 

on/off

 button (detail 7 - fig. 1) for 5 seconds.

fig. 2 - Turning the boiler off

When the boiler is turned off, the PCB is still powered. Domestic hot water and heating
are disabled. The antifreeze system remains activated. To relight the boiler, press the

on/off

 button (detail 7 - fig. 1) again for 5 seconds.

fig. 3

The boiler will be immediately ready to work whenever domestic hot water is drawn or in case of a
heating demand (generated by the Room Thermostat or the Remote Timer control).

B

The antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, DHW circuit and system; or
drain just the DHW circuit and add a suitable antifreeze to the heating system,
complying with that prescribed in sec. 3.3.

2.4 Adjustments
Summer/Winter Switchover

Press the 

summer/winter

 button (detail 6 - fig. 1) for 2 seconds.

The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate the Summer mode, press the 

summer/winter

 button (detail 6 - fig. 1)

again for 2 seconds.

Heating temperature adjustment

Use the heating buttons (details 3 and 4 - fig. 1) to vary the temperature from a min. of
30°C to a max. of 80°C; in any case, it is advisable not to operate the boiler below 45°C. 

fig. 4

DHW temperature adjustment

Use the DHW buttons (details 1 and 2 - fig. 1) to adjust the temperature from a min. of
40°C to a max. of 50°C.

fig. 5

Room temperature adjustment (with optional room thermostat)

Using the room thermostat, set the temperature required in the rooms. If the room ther-
mostat is not installed, the boiler will keep the system at the set system delivery setpoint
temperature.

Room temperature adjustment (with optional remote timer control)

Using the remote timer control, set the required temperature in the rooms. The boiler will
adjust the system water according to the required room temperature. For operation with
remote timer control, please refer to the relevant instruction manual.

eco

comfort

reset

9

15

13

12

11

8

1

3

6

7

10

2

16

4

14

5

17

I I I I

II

II

I

I I I I

II

II

I

Содержание DOMIcondens HE 26 C

Страница 1: ... cod 3540Z852 Rev 01 08 2012 DOMIcondens HE 26 C 700 400 330 196 85 115 200 INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Страница 2: ...ating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency Please see installation and servicing guidelines Ferroli declare that no substances harmful to health are contained in the appliance or used during the appliance manufacture B This symbol indicates Caution and is placed next to all safety warnings Strictly follow these inst...

Страница 3: ...display detail 11 fig 1 shows the actual heating delivery temperature and during heating standby time the message d2 Domestic hot water DHW A DHW demand generated by drawing domestic hot water is indicated by flashing of the hot water under the tap on the display The display detail 11 fig 1 shows the actual DHW outlet temperature and during DHW standby time the message d1 Comfort A Comfort demand ...

Страница 4: ...SHIP Incorrect installation can cause damage or injury for which the manufacturer declines any responsibility Installation of this unit must be carried out in strict compliance with the present instructions and the following regulations applicable in Great Britain Gas Safety Regulations Installations Use Local Building Regulations The Building Regulations Part L The Buildings Standards Scotland Co...

Страница 5: ...and the circuit with the non return valve at least 3 m from the boiler or an expansion tank for domestic use For installation follow the instructions contained in the kit Replenishing water It is necessary to provide for replenishing of the water lost by the sealed system Refer to standard BS6798 for the methods of filling and replenishing water in sealed systems There must not be a direct connect...

Страница 6: ...e following extraction suction systems Before installation check and carefully observe the above prescriptions Also comply with the provisions concerning the positioning of wall and or roof terminals and the minimum distances from windows walls vents etc Expansion A For fume exhaust pipes longer than 1 metre during installation take in account the natural expansion of the materials when the boiler...

Страница 7: ... case in areas with different pressures The exhaust and intake must not be positioned on opposite walls C6X Intake and exhaust with separately certified pipes EN 1856 1 B2X Intake from installation room and wall or roof exhaust IMPORTANT THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION Separate ducts Max permissible length 55 meq Baffle to use 0 15 meq Ø 45 15 35 meq Ø 50 35 55 meq No baffle...

Страница 8: ...s to the setting q02 displaying the actually saved value by pressing the DHW buttons If the pressure gauge reading is different from the nominal maximum pressure pro ceed by increases decreases of 1 or 2 units of parameter q02 by pressing the DHW buttons the value is stored after each modification wait 10 seconds for the pressure to stabilise Press the heating button ref 3 fig 1 The card goes to t...

Страница 9: ...thermostat fault Exchangers dirty clogged on water side Clean the exchangers Faulty water circulation Fume thermostat contact open Check the thermostat Wiring disconnected Check the wiring F05 Fume pressure switch fault contact fails to close Wrong card parameter setting Check the card parameter and modify it if necessary Fan fault Wiring disconnected Check the wiring Faulty fan Check the fan Card...

Страница 10: ...lied 14 Safety valve 81 Ignition and detection electrode 16 Fan 114 Water pressure switch 19 Combustion chamber 126 Contact fume thermostat 20 Burner assembly 138 External probe not supplied 21 Main nozzle 139 Room unit not supplied 22 Burner 145 Pressure gauge water gauge 26 Combustion chamber insulation 193 Trap 27 Copper exchanger for heating and hot water 277 Recuperator 28 Fume manifold 278 D...

Страница 11: ...ar 2 Max gas delivery G20 m3 h 2 64 Min gas delivery G20 m3 h 1 06 Burner nozzles G31 no x Ø 11 x 0 79 Gas supply pressure G31 mbar 37 Max gas pressure at burner G31 mbar 35 0 Min gas pressure at burner G31 mbar 5 0 Max gas delivery G31 kg h 1 96 Min gas delivery G31 kg h 0 78 Max working pressure in heating bar 3 PMS Min working pressure in heating bar 0 8 Max heating temperature C 90 tmax Heatin...

Страница 12: ...6 C 12 EN cod 3540Z852 Rev 01 08 2012 5 5 Wiring diagram fig 26 Electrical circuit 81 1kW L N 230V 50 Hz 16 N L 32 L N T T 278 T 42 4 3 2 1 44 38 114 ABM01 193 126 ON DAY 22 0004 REMOVE TO CONNECT THE CLOCK 139 138 72 ...

Страница 13: ......

Страница 14: ...ffect the customer s statutory rights If yes and if required by the manufacturer has a water scale reducer been fitted CONDENSING BOILERS ONLY The condensate drain has been installed in accordance with the manufacturer s instructions and or BS5546 BS6798 Yes If the condensate pipe terminates externally has the pipe diameter been increased and weatherproof insulation fitted Yes ...

Страница 15: ...eer Name Company Name Telephone No Gas Safe Register No Comments Signature Date Engineer Name Company Name Telephone No Gas Safe Register No Comments Signature Date Engineer Name Company Name Telephone No Gas Safe Register No Comments Signature Date Engineer Name Company Name Telephone No Operative ID No Comments Signature Date Engineer Name Company Name Telephone No Gas Safe Register No Comments ...

Страница 16: ...rvice Centre on 0843 479 0479 Calls to these numbers are charged at National Rate from BT landlines Calls made from mobile networks may be considerable more Phone numbers Installer Service Engineer BECAUSE OF OUR CONSTANT ENDEAVOUR FOR IMPROVEMENT DETAILS MAY VARY SLIGHTLY FROM THOSE QUOTED IN THESE INSTRUCTIONS ALL SPECIFICATIONS SUBJECT TO CHANGE Please note to avoid incurring unnecessary expens...

Отзывы: