Pag 10
Auxiliary output timing - AUX (A/)
1
2
3
4
5
6
7
8
9
A
0
B
Master Code (1480)
A7
1480 A7 10
1º
Entre the programming mode:
3º
Key in the new activation timing or
bistable mode
2º
Key in option:
beep (x4)
Example:
Change auxiliary output timing
to 10 seconds.
beep (x4)
beep (x4)
00: Generates alarm tone
01..99: (01 to 99 sec.)
Door sensor timing (A8)
1
2
3
4
5
6
7
8
9
A
0
B
Master Code (1480)
A8
1480 A8 15
1º
Entre the programming mode:
3º
Key in the new door sensor timing
2º
Key in option:
beep (x4)
Example:
Enable the sensor for open door
detection after 15 seconds.
beep (x4)
beep (x4)
00: Disabled
01..99: (01 to 99 sec.)
The auxiliary output (AUX) activation time can be programmed with any value from 00 to 99
seconds.
If the timing is set with value 00, the Memokey generates an alarm tone for 20 seconds (in
those cases mentioned previously), and a loudspeaker can be connected to the auxiliary
output (the other end of the loudspeaker must be connected to a positive power supply).
Any value different from 00 represents the time that the auxiliary output is activated delivering
125 mA.
If you wish to enable the door sensor you must use this option to enter the time (01 to 99
sec.) that is to elapse from when the door opens until it closes without setting off any
alarm incidents. Any such incidents will be transmitted by the AUX output, depending on
the configuration as mentioned previously.
If the value entered is 00, the door sensor is disabled.
Anti-sabotage protection
The system is fitted with anti-sabotage protection, so that after the introduction of 5
wrong codes via the keypad, it is blocked for 5 minutes, emitting deterrent beeps during
this time.
After one minute on standby, the failed attempt counter is reset.
If the AUX output is activated (A6=1) and the AUX output timing is other than 00 (A7
between 1 and 99), this output will be reactivated, indicating that an alarm incident has
occurred.
Содержание MEMOKEY 97023