Pag 12
A0
New Master Code
A1
New Free Access Code
1480 A0 1234
1480 A9 5678
A5
1: Enabled
0: Disabled
1480 A5 1
1480 A5 0
A2
00: Bistable mode
01..99 (01 to 99 seconds)
1480 A2 00
1480 A2 05
A3
4, 5 or 6
1480 A3 4
A4
1: Pushbutton enabled
0: Pushbutton disabled
1480 A4 1
1480 A4 0
A6
1: Enabled
0: Disabled
1480 A6 1
1480 A6 0
A7
00: Loudspeaker alarm tone
01..99 sec. (AUX activated 125 mA)
1480 A7 00
1480 A7 12
A8
00: Disabled
01..99: Enabled (01 to 99 sec.)
1480 A8 00
1480 A5 15
A9
Master Code (1480)
1480 A9 1480
AA
00...99: Memory position of code
to be deleted
1480 AA 02
00...99
Master Code
(1480)
1480 02 1144
Access code (4 to 6 digits)
Authorisation and allocation of access codes (100 codes)
Delete a code
Master code programming
Free access programming (trade)
Relay activation timing programming
Change code length from 4 to 6 digits
Enable/disable exit B pushbutton
Enable/disable possibility that users may change their own codes
Programmimg auxiliary output alarm or incidents alert function
(designated 'AUX')
Programming auxiliar output activation timing
Programmimg open door sensor timing
Delete all codes
00...99
A A
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
Function description
Function code
FAST PROGRAMMING GUIDE
Sequence of codes to be entered:
+
+
+
+
+
+
+
+
+
+
Example
1
2
3
4
5
6
7
8
9
A
0
B
+
+
+
Memory position
Содержание MEMOKEY 97023