2. INSTALLATION INSTRUCTIONS
The instructions in his paragraphs are specifically intended for qualified technicians and installers.
Under no circumstances shall
FERLUX Chimeneas y Barbacoas
be responsible for the final installation of the device.
The
correct installation of the device
shall always be the responsibility of the installer
, as shall adherence to the regulation in force in each region.
2.1 Prior requirements and location of the device
For the very principle of the functioning of the device, which works via combus-
tion of firewood, it is necessary to
ensure a supply of oxygen
(present in the
atmospheric air) so that combustion can take place, therefore it must be located
in a room with
adequate recirculation
of interior air and windows. Therefore,
if necessary, install an air vent
to ensure sufficient supply or oxygen without
affecting the quality of interior air.
We recommend that you
install the device in a location favourable to the
distribution of hot air, with no obstacles that hinder the flow or intake of
air for the device itself.
Similarly, it is possible to take advantage of an existing
fireplace in good condition to install a device provided it is built with non-com
-
bustible materials.
In any case, it is necessary for
the base upon which the device is to be set to
have sufficient bearing capacity
for the weight. The device must be perfectly
level when installed, on both the horizontal and the vertical plane, making use of
the adjustable legs for same.
For the FORNO ENCASTRADO model, we recommend that you leave a
safe
distance between the devices and the combustible materials of at least
100 mm at the sides and back and 150 mm at the front.
The covering must
also be made from material that can withstand high temperatures without under-
mining its physical and aesthetic provisions. Avoid, therefore, any form of wallpaper, carpeting, plastic or certain types of compacted
quartz. It is also necessary to
have two grates on the enclosure to allow decompression of the chamber and circulation of air
through same.
For the FORNO VISTO and FORNO LEÑERO models you must
position the device a minimum distance of 1,000 mm from any
combustible material
and taking into account the accessibility of same for cleaning, maintenance and installation tasks.
Dimensions FORNO VISTO (L) FORNO ENCASTRABLE (centre) and FORNO LEÑERO (R)
Sketch of built-in installation
11
23
761
595
381
17
6
20
0
11
49
851
70
11
23
566
742
371
17
6
20
0
15
62
761
595
200
381
17
6
rejilla
rejilla
máx. 65 ˚ C
máx. 50 ˚ C
máx. 65 ˚ C
máx. 50 ˚ C
100 mm
aislante