4.5 Connecting and Setting the Alarm Kit (optional)
The solution provided here presumes that all alarm indicators (buzzer) are wired in parallel and
switched through the relay X11 on the ID ISC.LR2000-A-M Reader. The pulse duration can be set
(CFG2 / REL1) between 100 ms and 6553.5 s by adjusting the Reader configuration. Relay X11
provides a changeover contact for low voltages.
4.5.1 Installing the Alarm Indicators
The acoustic indicator, the buzzer, is installed in the antenna base as shown in Fig. 18. For the
installation you have to use the attached mounting bracket and the screws. The volume can be
adjusted with the attached manual volume controller which has to be mounted first.
Fig. 18: Installing the buzzer
4.5.2 Connecting the Indicators
The indicators are connected as shown in . The red wire (+) ahs to be connected with terminal 5
and the black wire (GND/-) has to be connected with terminal 4 of the terminal block.
Corresponding to that the wires have to be connected to the buzzer.
Notes:
The relay outputs are dimensioned for max. 24 V DC / 2 A.
The relay outputs are intended only for switching resistive loads. If an inductive load is used,
the relay contacts must be protected by an external protection circuit.
Reversing the polarity or overloading the outputs will destroy them.
See also Installation Manual ID ISC.LRM2000-A/B