![Feig Electronic OBID i-scan ID ISC.ANT1300/680-A Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-ant1300-680-a/obid-i-scan-id-isc-ant1300-680-a_installation-manual_3900030016.webp)
OBID i-scan
®
Installation
ID ISC.ANT1300/680-A
FEIG ELECTRONIC GmbH
Page 17 of 50
M71104-1e-ID-B.doc
4.2.3 Mounting of the components at the use of the Power Splitter
Step
Action
Note
1
Mounting of the
reader with the screw
M4x8 Pos.13
2
Mounting of the
Power Splitter with
the hexagon spacer
bolts M3x6 Pos.11
and the screws M3x6
Pos.12
3
Mounting of the Ter-
minal block Pos.8
with the screws
M3x10 Pos.10 and
connection of the
terminals 1+2 (+24V)
and 3+4 (GND) with
the bridges. Pos.9
4
Mounting of the relay
cable Pos.1 with
1 piece of cable tie
2,5x105mm Pos.6
Red wire to Com and
Brown wire to NO of
X9 Reader, Red wire
to 2 and Black wire to
5 of terminal block
11.
12.
9.
10.
Brown
Red
Brown
Red
6.
X9