OBID i-scan
®
Installation
ID ISC.ANT1300/680-A
FEIG ELECTRONIC GmbH
Page 18 of 50
M71104-1e-ID-B.doc
5
Mounting of the DC-
cables Pos.2 of the
readers and of the
PS with 2 pieces of
cable tie 2,5x105mm
Pos.6
Attention! Take care
of polarity.
6
Connect DC- cables
to Terminal block
Red wire to terminal
1+2 (+24V), Black
wire to terminal 3+4
(GND)
. Attention! Take care of polarity.
7
Connect the antenna
cable with X3 of PS.
Wind up the rest of
the cable to loops
and tied it together
with 2 pieces of cable
tie 4,8x280mm Pos.5
8
Mounting of the
1,35m coaxial cable
between X1 Reader
and X1 PS. Mount
the torrid from the
reader attachment
approx. 10cm with 4
turns before the
reader.
9
Wind up the rest of
the cable to loops
and tied it together
with 2 pieces of cable
tie 4,8x280mm Pos.5
and place it in the
antenna foot.
X1
X3
X1