OBID i-scan
®
Installation
ID ISC.ANT1300/680-A
FEIG ELECTRONIC GmbH
Page 33 of 50
M71104-1e-ID-B.doc
Step
Action
Note
6
CFG1: Interface and Mode
To tune, activate “ISO-Host
Mode”
7
Set by clicking on “Write”
8
CFG15:
Antenna Multiplexing
Ι
Activate „Multiplexing“
Configure the parameters as
follows:
•
„Switching Condition“ –
after no response
•
„Number of Input
Channels“ – 1 Input
(Single Mode)
•
„MUX-Valid Time“ – 100 x
5 ms
•
„Number of Output
Channels“ => 2
9
Set by clicking on “Write”