OBID
®
classic-pro
Manual
ID CPR.03.20-CD
FEIG ELECTRONIC GmbH
Page 35 of 40
H60100-5e-ID-B.doc
7.2.3. Programming the firmware
Î
'FLASHALL' command
The return key can be pressed to test the connec-
tion. The 'Bootloader' prompt should appear once
again.
Enter the command: '
FLASHALL
' in capital letters
next to the prompt.
NOTE:
The power supply to the reader should not be interrupted after sending the 'FLASHALL'
command!
This is acknowledged by the reply '
ERASE WAIT
'. A few seconds later the '
Start DOWNLOAD
'
message will ask you to send the new firmware file to the reader.
You have approximately 2 minutes to do this. During this time the characters 'C' or '§' appear ap-
proximately every 5 secs. If no mhx file has been sent to the reader during this time the following
error message appears: 'ERROR 1'. After this you must enter the '
FLASHALL
' command again.
Do
not
switch the reader off.
Using the 'Send' button in the main menu it is possible to open
the 'Send file' dialog.
Ensure that the '
Xmodem
' protocol and the
new mhx file are selected and press the
'Send' button.
The subsequent programming process
takes a few seconds.