OBID
®
classic-pro
Manual
ID CPR.03.20-CD
FEIG ELECTRONIC GmbH
Page 14 of 40
H60100-5e-ID-B.doc
4. Normal Operating Mode
Idle State (no Transponder detected):
In idle state the reader is searching permanently for a Transponder. In this case the red
LED is active.
Transponder detected:
After a Transponder is detected by the ID CPR.03.20-CD the data's are transmitted via
data-/clock interface once and the beeper sounds for a short time. At the same time the
red LED turns off for a period of 2 sec.
To transmit the data's a second time the Transponder must leave the detection field of the
ID CPR.03.20-CD for more then 1,5 seconds.
UID Length Error
If the Transponder UID is shorter than configured in ID CPR.03.20-CD a length error is
signalized with 2 short beeps. In this case no data's are transmitted via data-/clock inter-
face.
Example
Transponder according ISO14443-A, 4 Byte (32 Bit) UID size
D_START = 16, D_LGT = 24
⇒
D D_LGT = 40
⇒
UID will not trans-
mitted.
MSB................................................LSB
UID hex 7 D 2 D 6 9 2 1
UID bin 0111 1011 0010 1101 0110 1001 0010 0001
|<-........-- D_LGT = 24 ------------|
`- D_START = 16
4.1. Digital Inputs
LED red:
Activates the red LED, as long as the input is connected to GND.
LED green:
Activates the green LED and deactivates the red LED, as long as the input is connected to
GND.
Beeper:
Activates the beeper LED, as long as the input is connected to GND.
Hold: