OBID
®
classic-pro
Manual
ID CPR.03.20-CD
FEIG ELECTRONIC GmbH
Page 25 of 40
H60100-5e-ID-B.doc
D_DIGIT (0 ... 20):
This parameter defines the number of BCD signs (excluding start sign, stop sign and
LRC) which will be transferred via data-/clock interface if INTERFACE = 0x01 (Magstripe
Track II, binary) or INTERFACE = 0x02 (Magstripe Track II, decimal is selected).
The following additional conditions are defined
D_DIGIT > 20
⇒
D_DIGIT = 20
D_DIGIT > D_LGT*4
⇒
missing most significant digits are filled with '0'
D_DIGIT < D_LGT*4
⇒
truncates the most significant digits of the UID
SCAN-DATA
This parameter defines the data which are read and transferred by the reader.
Bit:
7
6
5
4
3
2
1
0
DBO
DATA-
SELECTION
DATA-SELECTION:
Configures the reading of UID or DATA-BLOCK
b000
UID of the configured transponder (see parameter TAG_DRV)
b001
mifare standard DATA-BLOCK*
b010
mifare ultra-light DATA-BLOCK*
b011
SLE55xx public DATA-BLOCK*
b100
ISO 15693 DATA-BLOCK*
*NOTE:
If DATA-BLOCK reading is selected make sure that the required TAG_DRV
is enabled.
DBO:
Definition of the byte order if DATA-BLOCK reading is configured:
b0:
MSB fist - The most significant data byte is transferred at first
b1
LSB first - The least significant data byte is transferred at first
DB_ADR:
If DATA-BLOCK is selected in SCAN-DATA this parameter defines the absolute physical
Transponder address of the first DATA-BLOCK, which will be transferred. The maximum
address depends on the memory size and organization of the respective Transponder
(see ANNEX C: Memory Organization of Supported Transponders)
mifare_KEY:
6 byte key which is used for the authentication at a mifare 1 k or mifare 4 k to read a
DATA-BLOCK.
The selection of key-A or key-B can be done by the parameter TAG_DRV.MK.