OBID
®
classic-pro
Manual
ID CPR.03.20-CD
FEIG ELECTRONIC GmbH
Page 34 of 40
H60100-5e-ID-B.doc
Enter the connection settings in the COM port
Properties dialog:
If, after pressing 'OK', the message: 'COM1
could not be opened......' appears, the COM
port is probably being used by a different ap-
plication.
7.2.2. Reader synchronisation
Î
'PPPPPPPP...'
NOTE
Use capital letters only for command input!
1. Start sending 'P' characters (0x50)
2. Switch on the reader's power supply while sending 'P' characters.
Synchronize the PC interface to the reader interface
by sending at least 15 'P' characters (0x50).
The reader replies with the bootloader prompt, the
red LED lights up.
It then waits for a maximum of 8 seconds for a
bootloader command input (FLASHALL, VERIFY,
RESET). If it receives either no command or only a
wrong one it leaves the bootloader mode.