UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 57 of 117
H71011-0e-ID-B.docx
DUPLEX:
(HostInterface.LAN.Autonegotiation.Duplex)
b0:
Half Duplex
b1:
Full Duplex
SPEED:
(HostInterface.LAN.Autonegotiation.Speed)
b0:
10 Mbit
b1:
100 Mbit
DHCP:
(HostInterface.LAN.IPv4.Enable_DHCP)
b0:
DHCP client disable
b1:
DHCP client enabled
KEEP-CNT:
(HostInterface.LAN.Keepalive.RetransmissionCount)
Specifies the maximum number of retransmissions. This is the number of times that the
reader re-transmits a keepalive packet to the host to check for connectivity. The valid range
is 1..255.
KEEP-INTERVAL:
(HostInterface.LAN.Keepalive.IntervalTime)
Set the Keepalive Interval. This is the polling frequency used to determine if a keepalive ex-
change is needed. This interval is used when the connection failed. The valid range is
1..255 sec.
NOTE:
The command has no effect on this setting
Changing of this parameter only becomes effective after writing / saving this configuration
block to EEPROM and a [0x64] System Reset of the RFC.