UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 39 of 117
H71011-0e-ID-B.docx
7.8. CFG10: Trigger
The configuration block contains parameters for the trigger configuration.
Byte
0
1
2
3
4
5
6
Contents
TRIGGER-
MODE
TRIGGER-
USE
0x00
0x00
TRIGGER_2-HOLD-TIME
0x00
Default
0x00
0x00
0x0005
500ms
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
ACTION
Default
0x00
TRIGGER-MODE
defines the mode of the scanner.
Bit
7
6
5
4
3
2
1
0
Function
Trigger
0
Condi-
tion
0
0
0
0
Unlimited
Valid Time
Trigger:
(
OperatingMode.BufferedReadMode.Trigger.Enable
)
(
OperatingMode.NotificationMode.Trigger.Enable
)
b0:
Trigger disabled:
The Reader RF Power is on and the Reader scans all the time in BRM
Mode.
b1:
Trigger enabled:
The Reader start the RF Power and the scan, if the trigger is activated
by the external switch.
NOTE:
If Trigger is enabled and not activated by the external switch, the RF-field will be switched
off.