UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 102 of 117
H71011-0e-ID-B.docx
11.4. [0x72] Set UPC output
The command Set UPC Output is used to control the Alarm LED of the DM. Each output takes on
the state defined by the byte OUTx-mode for the period of time (OUT-TIME) included in the proto-
col. The flashing frequency is defined by the byte OUTx-frq. Via this protocol the outputs can be
switched on or off for the indicated period of time. If the UPC receives a command Set UPC Out-
put, all times that have been active until then are being overwritten by the new times included in
the protocol if they are
0.
Host
UPC
1
2,3
4
5
6
7
0x02
n
UPC_ADR
[0x72]
Mode
OUT-N
8
9
10,11
n-1...n
OUT-NR
OUT-S
OUT-TIME
CRC16
Repeated OUT-N times
Host
UPC
1
2,3
4
5
6
7,8
0x02
8
GPC-ADR
[0x72]
STATUS
24
CRC16
UPC-ADR:
0: bus address of UPC
Mode:
0x01 (reserved)
OUT-N:
Defines the number of output records. N = 1
OUT-NR:
Defines the Type and the number of the output
Bit:
7
6
5
4
3
2
1
0
Function:
OUT-type
OUT-Number
OUT-type:
b000
Digital Output, not supported by DM
b001
LED
b002
Buzzer, not supported by DM
OUT-Number:
1
24
see
Fehler! Verweisquelle konnte nicht gefunden werden.