NOTE:
The internal system timer is not a real time clock (RTC) and the accuracy cannot be guaran-
teed.
Extension:
b0:
extension flag disabled, Data from TR-Data2 will not be requested
b1:
extension flag enabled, Data from TR-Data2 will be requested
TR-DATA-2:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
-
-
DIREC
TION
-
-
-
MAC
IN
DIRECTION:
(
OperatingMode.BufferedReadMode.DataSelector.Dxxxx
)
(
OperatingMode.NotificationMode.DataSelector.Dxxxx
)
b0:
no Direction states will be stored
b1:
Direction states will be stored
MAC:
b0:
The MAC-Address of the Reader will be not transmitted.
b1:
The MAC-Address of the reader will be transmitted.
IN:
(
OperatingMode.BufferedReadMode.DataSelector.InputEvents
)
(
OperatingMode.NotificationMode.DataSelector.InputEvents
)
b0:
no Input states will be stored
b1:
Input states will be stored